Standard
- UL 2580
Technical Parameters
Product Name | Complex Salt Spray Test Chamber | |
Model No. | BE-8209-12m³ | BE-8209-15m³ |
Internal Dimension | W2000 X D3000 X H2000 mm | W2500 X D3000 X H2000 mm |
External Dimension | W2400 X D5000 X H3000 mm | W2900 X D5000 X H3000 mm |
Max Load | 1000KG for battery pack | |
Temp. Range | 0℃~+85℃ | |
Temp. Fluctuation | ±0.5℃ | |
Temp. Deviation | 2℃ | |
Spray Capacity | 1~2mL/80cm2/hr (Collect at least 16 hours, take the average ) | |
Spray Pressure | 1.00±0.01kgf/cm² | |
Resolution | Temp: 0.01℃, Humidity:0.01%R.H. | |
Humidity Range | 30%–98%R.H. | |
Humidity Fluctuation | ±3%R.H. | |
Potion PH | Neutral 6.0~7.0 Acidity 3.0~3.1 | |
Spray Solution PH | Neutral 6.5~7.2 Acidity 3.1~3.3 | |
Test Time Range | 1S ~ 9999H (Settable) | |
Control Mode | Touch screen programmable control PLC, networking; mobile phone APP alarm; with USB interface, with RJ485 interface can be connected to computer control, exclusive network control software. Remote monitoring and data acquisition. | |
Internal material | Acid and alkali resistant SUS316 material | |
External material | Cold and heat resistant steel plate with spray coating | |
Cooling Mode | Air cooling / water cooling | |
Total Weight | Approx 7 Tons | |
Power Supply | AC 380V, 55KW | |
Other Auxiliary Functions | *Main-subsidiary type trolley for the specimen in and out of the test chamber.*Explosion-proof, Pressure relief, Smoke Exhaust, Fire extinguishing, Video monitoring. |