Thermal Abuse Test Chamber Standards
- IEC 62133
- IEC 62619
- UL 1642
Relevant standards requirement
Single storage cell Safety Test
Heating test steps:
- Charge the battery according to the standard 6.1.3
- Place it into the chamber
–For lithium storage battery, the oven temperature is raised at a rate of 5℃/min to the temperature of 130℃±2℃, remain this temperature for 30min, then stop heating.
–For metal cyanide nickel battery, the oven temperature is raised at a rate of 5℃/min to a temperature of 85℃±2℃, remain this temperature for 2h, then stop heating.
- Observe for 1h
Storage Battery Module Safety Test
- Charge the battery module according to the standard 6.1.4
- Place it into the chamber
-For lithium storage battery, the oven temperature is raised at a rate of 5℃/min to a temperature of 130℃±2℃, remain this temperature for 30min, then stop heating.
–For metal cyanide nickel battery, the oven temperature is raised at a rate of 5℃/min to a temperature of 85℃±2℃, remain this temperature for 2h, then stop heating.
- Observe for 1h
Thermal Abuse Test Chamber Technical Parameters
Model | BE-101-1000A |
Temp. Range | Ambient – 200℃ (Controllable) |
Control Accuracy | ±0.5℃ |
Temp. Uniformity | ±2.0℃( No load) |
Temp. Rising Speed | RT – 150℃ (≧5℃/min, liner with load 40kg module) |
Temp. overshoot | ≦2.0℃ |
Control Display Method | PLC Touch screen + remote control, networking, |
Cell phone APP alarm device, with USB interface, R485 interface can be connected to computer control. | |
Testing Room Dimension | W1000 X D1000 X H1000 mm |
External Chamber Dimension | W1400 X D1300 X H1840 mm |
Inner chamber Material | SUS304 Stainless Steel (Mirror finished) |
External chamber Material | SECC Steel Plate, Powder Painted |
Basement | With universal wheel |
Observation Window | 390 X 360mm (20mm Tempered Explosion Proof Glass) |
Power Source | 380V 50HZ |
Heating Power | About 12 KW |
Safety Protection Device | over-voltage, over-temperature, over-current protection. |
protection for short circuits caused by incorrect operation of the operator and battery electrode, battery positive and negative connection, etc. | |
Safety Device | Smoke exhaust system, explosion-proof pressure relief port, tri-color light alarm. |