Application
The Temperature Humidity Vibration Combined Test Chamber meets national standards and meets specific testing requirements. It is widely used in electrical and electronic products, automotive parts, materials, etc. through a combination of high and low temperature, low temperature, temperature change, impact, wet heat vibration and other environmental reliability tests.
Features
- With high precision perfect external design, external with double sides cold-rolled plate electrostatic powder-coated material, internal with SUS#304 high temperature resistant stainless steel.
- Insulation material adopts fire resistant high strength PU polyurethane foaming thermal insulating material.
- More than 20% of energy saving is achieved &thanks to the introduction of Japan & German advanced refrigerator control technology.
- Control system and control circuit components all introduced with famous brands.
Standard Compliance
- IEC 68-2-1 (GB2423.1-2008)
- IEC 68-2-2 (GB2423.2-2008)
- IEC 68-2-3 (GB2423.3-2006)
- IEC 68-2-30 (GB2423.4-2008)
- IEC 68-2-14 (GB2423.22-2008)
- MIL-STD-810D (GJB150.3A-2009)
- MIL-STD-810D (GJB150.4A-2009)
- MIL-STD-810D (GJB150.9A-2009)
Performance parameters
Model | BTHZ-408 | BTHZ-800 | BTHZ-1000 |
---|---|---|---|
Internal Dimension | 600x850x800 | 1000x1000x800 | 1000x1000x1000 |
W x H x D(mm) | |||
External Dimension | 850x1650x1500 mm | 1250x1750x1600 | 1250x1750x1800 |
W x H x D(mm) | |||
Temp. Range | B:-20~150℃ C:-40~150℃ D:-70~150℃ | ||
Humidity Range | 20-98%RH | ||
Temp. Fluctuation | ≤±0.5℃ | ||
Temp. Deviation | ≤±2℃ | ||
Temp. Uniformity | ≤±2℃ | ||
Humidity Fluctuation | ≤±2.5%RH | ||
Humidity Deviation | Temperature 75%RH: ≤+2,-3%RH;Humidity 75%RH: ≤±5%RH |