Battery Short Circuit Test Machine Relevant standard requirement
Single Storage Cell Safety Test
6.2.4 Short circuit
- Charge the single storage cell according to 6.1.3 standard
- The cell is to be short-circuited by connecting the positive and negative terminal with an external resistance of less than 5mΩ for 10 min
- Observe for 1H
Battery module safety test
6.3.4 Short circuit
- Charge the battery module according to standard 6.1.4
- The battery module is to be short-circuited by connecting the positive and negative terminal with an external resistance of less than 5mΩfor 10 min
- Observe for 1H
Standard
- UL 2580
Technical Parameters
| Model | BE-XL-2000A | BE-XL-3000A | BE-XL-5000A |
|---|---|---|---|
| Max. Operating Current(A) | 2000A | 3000A | 5000A |
| Max. Instantaneous Current(A) | 3000A | 4000A | 6000A |
| Temp. Range | Ambient Temperature | ||
| Inner Resistance | <1mΩ,<5mΩ,<10mΩ,<20mΩ,<50mΩ,<100mΩ(Optional) | ||
| Control Mode | PLC Touch Screen + Computer remote control + Remote controller | ||
| Overall Dimension | W700xD1050xH1830mm | ||
| Explosion proof Chamber Dimension | 800 X 800 X 800mm,1000 X 1000 X 1000mm (Optional) | ||
| Voltage Measurement Range | 0~500V | ||
| Short Circuit Response Time | ≦20ms | ||
| Data Interface | USB, Data card, etc. | ||
| Data Acquisition Module | Independent remote acquisition, multi-voltage/temperature/current acquisition channels ensure data accuracy. Acquisition frequency 100HZ | ||
| Short Circuit Mode | Pneumatic + vacuum arc extinguishing | ||
| Safety Device | Electric leakage, over current protection ,smoke alarm device, abnormal sound light alarm. | ||
| Testing Fixture | Customize according to actual testing condition | ||
| Power Supply | 220V 50HZ | ||