Standards
- IEC 62133-2017
- UL 1642
- GB 31241-2014
Main technical parameters
Model | BE-8103 |
---|---|
Structure | All-in-one structure, the door uses explosion-proof lock + explosion-proof chain |
Normal temperature to 150°C (Adjustable) | |
Temperature Range | |
Controlling Accuracy | ±0.5℃ |
Temperature Deviation | ±2.0℃, No load |
Heating Rate | RT~150°C (Linear 5°C/min) |
Control Display | PLC touch type (7 inch) + remote control |
Working Cabinet Dimension | W600XD500XH600 mm |
External Dimension | W940XD780XH1620 mm |
Inner Chamber Material | SUS304 Stainless steel with mirror-finish |
External Chamber Material | SECC steel plate, fine powder paint coating (thickness 1.5mm) |
Bottom | With universal wheel |
Observation Window | 390 X 360mm (20mm thick explosion-proof glass, explosion-proof mesh) |
Insulation Material | Imported high-density glass wool, good heat insulation, to ensure maximum temperature insulation, tight sealing materials for high temperature resistant silicone, withstanding high temperatures over 300 degrees for a long time |
Terminal Hole | Diameter 50mm Terminal hole on the left and right sides |
Power Supply | 220V / 50HZ / 4.0KW |
USB Interface | With USB interface, the test data can be exported |
Auxiliary Function | Explosion-proof pressure relief device, smoke exhaust device, explosion-proof lighting device, electronic door lock system, safety stop switch |
The heating test of battery thermal abuse test chamber shall be carried out as follows
1.Relevant standard test requirements
Single battery safety test
The heating test is carried out as follows:
- The single battery is charged according to the method of 6.1.3
- Put the single battery into the temperature chamber.
- For lithium-ion batteries, the temperature chamber is increased from room temperature to 130 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining the temperature for 30 minutes.
- For nickel metal cyanide batteries, the temperature chamber is raised from room temperature to 85 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.
- Observe for 1h.
2.Battery module safety test
- The battery module battery shall be charged according to the method in 6.1.4.
- For lithium-ion batteries, the temperature chamber is raised from room temperature to 130 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 30 minutes.
- For nickel metal cyanide batteries, the temperature chamber is raised to 85 ° C ± 2 ° C at room temperature at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.
- Observe for 1h.